01. PV Capacity
60 MWp (ground-mounted PV project, annual power generation of 66 million kWh)
A manufacturing facility that is a high-voltage dedicated transformer user operating at 10 kV or higher. Production loads are significantly higher during daytime hours and on weekdays than at night or on holidays. This is one of the scenarios where the “rooftop PV + customer-side energy storage” model offers the greatest economic viability, featuring a high proportion of self-consumed PV power, while energy storage can be used for peak-valley arbitrage, demand response, and distribution capacity relief.
Load Curve
High load during daytime on weekdays, baseline load maintained at night, and reduced load on weekends and holidays.
Key Equipment
Production lines, electric motors, air compressors, kilns/heating equipment, cooling systems, air conditioning, circulation pumps, plant utility systems.
Electricity Consumption Patterns
Highly correlated with production schedules, with distinct peaks in the morning and afternoon; electricity consumption is even higher during high summer temperatures.
Billing Characteristics
Primarily dual rate structures, demand charges or capacity charges have a significant impact on billing statements.
Electricity costs account for a significant portion of manufacturing costs, and peak-hour and super-peak electricity rates have a major impact on production costs.
Power rationing or load shedding disrupts continuous production, and the losses from production line downtime may far exceed the electricity costs themselves.
Short-term load spikes may lead to insufficient transformer capacity; capacity expansion involves long lead times and high investment costs.
Although rooftop space is abundant, PV output does not perfectly align with production loads; energy storage is needed to improve grid integration and maximize returns.
60 MWp (ground-mounted PV project, annual power generation of 66 million kWh)
10MW / 20MWh
The EMS integrates PV, energy storage, main transformer loads, production schedules, and time-of-use electricity rates to achieve demand response.
Charge during off-peak electricity rate periods (e.g., at night) to reduce electricity purchase costs.
Discharge stored energy during peak electricity rate periods to replace high-cost grid purchases.
Make appropriate adjustments during off-peak periods based on production load requirements; prioritize solar power to meet the load, and feed excess electricity into the energy storage system.
When the main transformer load approaches the demand threshold, the energy storage system enters demand control mode to limit peak demand and reduce demand-based electricity charges.
In the event of a grid failure or power rationing, the energy storage system can quickly switch to off-grid mode to provide uninterrupted power to critical loads.
Cost Reduction and Efficiency Improvement
Reduce electricity costs through peak-off-peak arbitrage and demand management.
Green Energy Consumption
Increase the self-consumption rate of solar power to over 90% to avoid curtailment.
Grid Stability
Mitigate load fluctuations and improve power quality
Emergency Suppor
Ensure uninterrupted power supply to critical production loads during grid failures or power rationing.